Product Overview
IE3 Industrial Induction Motor refers to an IE3 motor built on the squirrel-cage induction principle. Three-phase current in the stator creates a rotating field and induces current in the rotor bars, so torque is produced without brushes, slip rings or any rotor supply.
That simplicity is why induction motors dominate industry: few wearing parts, tolerance to dust and moisture in an IP55 enclosure, and bearings as the main maintenance item. Class F insulation and cast aluminium rotor bars support S1 continuous duty. IE3 efficiency comes from lower iron and copper losses than IE2 motors, which typically means around 15 to 20 percent less wasted energy and a cooler-running winding.
Starting is direct on line for most ratings, with a locked-rotor current of several times rated current; larger motors or weak supplies call for star-delta starters, soft starters or frequency drives.
Main points for buyers
- 1Confirm the efficiency class. Check the IE3 marking and ask for efficiency at 100, 75 and 50 percent load, not only the class label.
- 2Match rated speed, not only pole count. A small slip difference changes fan and pump power noticeably.
- 3Check the mechanical interface. Compare frame size, mounting (B3, B5 or B35), shaft diameter and flange with the driven equipment drawing.
- 4Lock down the electrical data. Confirm voltage, frequency and terminal connection before ordering, because special windings take longer than standard ones.
- 5Request the paperwork. Ask for CE and CCC documents, nameplate data and test reports so customs and your own customers have no questions.
When comparing quotations for IE3 Industrial Induction Motor, look beyond the ex-works price. Rated power and frame size set the material content, while copper and silicon steel prices move the figure from month to month. Special voltage, 60 Hz windings, a higher protection class, brakes or encoders add cost, as do test reports and OEM packaging. Order quantity, container loading, sea freight, import duty and local VAT then decide the landed cost per unit, so ask each supplier to quote on the same Incoterm and the same rating.
Typical specification of the IE3 Industrial Induction Motor. Values are standard offers; ratings, voltage and options can be adjusted to your order.
| Parameter | Standard Offer | Customization Options |
| Product type | Three-phase asynchronous induction motor, squirrel-cage rotor | ODM design from your working conditions |
| Model series | YE3 series | Private-label model name on the nameplate |
| Efficiency class | IE3 Premium Efficiency (IEC 60034-30-1) | Efficiency test report with the shipment on request |
| Number of poles | 2, 4, 6 or 8 | Pole count selected per order |
| Synchronous speed at 50 Hz | 3,000 to 750 rpm (2 to 8 poles) | Specify the pole count with the order |
| Rated speed at 50 Hz | 690 to 2,980 rpm depending on poles | Depends on power rating and supply frequency |
| Power range | 0.75 to 355 kW | Other ratings on request |
| Frame size | 80 to 355 | Special shaft or flange dimensions on request |
| Rated voltage | 380 V, 400 V or 415 V, three-phase | 220 V to 690 V and other voltages on request |
| Frequency | 50 Hz | 60 Hz winding and nameplate |
| Protection class | IP55 | IP56 or IP65 on request |
| Insulation and temperature rise | Class F insulation, Class B temperature rise | Class H insulation and thermistors on request |
| Duty type | S1 continuous | S2 to S8 on request after thermal check |
| Cooling method | IC411, totally enclosed fan-cooled | IC416 separate fan for VFD operation |
| Mounting | B3, B5 and B35 | V1 and other mounting forms |
| Housing material | Cast iron frame and end shields for most ratings | Aluminium frame on small ratings on request |
| Ambient and altitude | Minus 15 to plus 40 degrees C, up to 1,000 m | Higher altitude or temperature with derating |
| Options | Standard motor without options | Brake, encoder, space heater, explosion-proof, VFD-ready design |
| Certification and quality system | ISO9001, China CCC, EU CE | Inspection and test documents on request |
| Nameplate, color and packaging | Standard nameplate, standard color, export carton | OEM nameplate, RAL color, wooden case |
Final values for a given rating are confirmed on the datasheet issued with your quotation.
Application
The IE3 Industrial Induction Motor is used wherever a reliable, efficient three-phase drive is needed. The sections below cover typical industries, buyer types, selection and day-to-day use.
Application Scenarios
| Industry | Typical Equipment | Why It Fits |
| Conveying and material handling | Belt conveyors, feeders, screw conveyors | Standard IEC frame sizes fit common gearboxes and reducers |
| Mining and quarrying | Crushers, screens, ventilation fans | Continuous S1 duty and an IP55 enclosure handle dust and shock |
| Machine tools | Grinders, presses, hydraulic pump drives | Compact frames and steady torque for production machinery |
| Textile | Spinning, weaving and dyeing machinery | Stable speed and low vibration support consistent output |
| Lifting and port machinery | Auxiliary drives, winches, bulk handling | Robust housings and common mounting forms ease replacement |
Target Customers
Suitable and Unsuitable Uses
- General industrial drives with moderate to long running hours
- Machinery shipped to markets that require IE3
- Replacement of IE1 or IE2 motors with a matching frame
- Very short-duty or rarely used equipment where purchase price decides
- Explosive atmospheres unless an explosion-proof version is specified
- Loads with special torque needs that have not been checked with our engineers
Selection Guidance
- 1Define the load. Set required shaft power, starting torque and duty cycle before looking at models.
- 2Choose the speed or type. Choose the pole count from the driven speed, then confirm frame and mounting. For frequent starts, check the thermal duty with us before ordering.
- 3Set the environment. Note ambient temperature, altitude, dust, moisture and whether IP55 or higher is needed.
- 4Fix the interface. Confirm voltage, frequency, mounting type, shaft size and the documents your market requires.
Usage Notes
- Compare supply voltage and frequency with the nameplate before connecting, and stay within plus or minus 5 percent voltage.
- Check that the star or delta connection matches the nameplate and the supply.
- Measure insulation resistance before the first start, and again after long storage or damp conditions.
- Align the coupling or set belt tension correctly, since misalignment is a leading cause of early bearing failure.
- Keep the fan cover clear and leave space for airflow around the frame.
- Grease bearings at the interval in the manual, and keep to the permitted number of starts per hour.
- Fit overload and thermal protection, and respect the permitted number of starts per hour.
English
Español
عربى



